ZONE VALVE

Zone valve for your underfloor heating

Does downstairs get too warm when upstairs is heating? With a zone valve and suitable controls, upstairs and downstairs can each ask for heat separately. We install them.

DOES IT FIT?

Do you need a zone valve?

Three signs that your underfloor heating may not have its own zone.

Upstairs stays cold

Often the thermostat downstairs switches the boiler off as soon as the living room is warm.

Downstairs gets too warm

If upstairs and the floor run on the same boiler, the floor can heat up along with it when upstairs calls for heat, unless it has its own zone.

Only a mixing valve on the manifold

A mixing valve with a sensor only limits the water temperature. It does not close off a zone.

What you get from us

What you get

We fit the zone valve on the pipe to your manifold, connect the controls and set up the zones, in the app for tado and evohome. We supply the parts ourselves.

What it costs

We often prepare the quote based on your photos, each part listed separately, plus labour and call-out charge. Sending photos and a quote are free and without obligation. If we come and look first, that costs €139.15 incl. VAT, call-out charge included; we deduct one working hour (€90.75 incl. VAT) if you accept the quote. The price in the quote is fixed for 30 days.

WANT TO KNOW MORE? THE TECHNICAL DETAILS

How a zone valve works

  • Downstairs asks for heat: the valve opens.
  • Downstairs is warm enough: the valve closes.
  • Upstairs asks for heat: the boiler fires for the radiators, the floor stays closed if downstairs does not call for heat.
  • Own receiver: it controls the valve. If it is connected to the boiler, the floor can also call for heat on its own.

If there are already actuators on all loops of your manifold, you can sometimes do without a separate valve. A photo gives a first impression; if needed, we come and look on site.

WHICH SYSTEM

tado° X or Honeywell evohome

Tado X

We install Tado X. Usually one Receiver X on the boiler and one on the zone valve. If there is a thermostat wire in the right place, a wired Thermostat X is also an option. We supply the tado ourselves. Request it via the tado check.

Honeywell evohome

If you already have Honeywell evohome, you can usually stay with it. With the HCC100 you control up to 8 floor zones.

District heating

If each floor has its own manifold with a pump, a zone valve per manifold with a socket next to it is possible, and a thermostat per zone.

FAQs

Is your question not among them?

You will find more answers on our FAQ page.

What is the difference between a zone valve and a bypass?

A bypass lets the water keep circulating when all valves are closed. A zone valve does the opposite: it closes off a zone. They are two different parts. When the zone valve closes, a bypass is sometimes needed as well. We assess that from your photos and, if needed, on site.

No. A smart valve is made for radiators. The mixing valve on your manifold only limits the water temperature; it does not close off a zone. Read more in why upstairs does not warm up.

For a separate zone valve, usually yes: we drain (part of) the system and refill and bleed it afterwards. With block heating, the building manager or owners' association is sometimes needed for that. If there are already working actuators on all loops, nothing may need draining. If the system has to be drained for other work anyway, that is a good moment to add the zone valve.

A photo of the whole manifold with the flow and return pipes, of your thermostat and, if you have your own boiler, of what is underneath it. If you know whether a wire runs to the boiler, add that too. That gives us a first impression of what is already there.

If those two zones are on one manifold, one zone valve is not enough. Then we usually fit a controller with an actuator per loop. We check that on your photos.

ADVICE

Control upstairs and downstairs separately?

Send photos of your manifold and thermostat, as in the questions above. You will hear from us within 2 working days. After that we let you know whether we can make a quote or come and look first. We work in the Randstad, up to about 60 km from Utrecht.